Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Pediatr Cardiol ; 45(2): 272-281, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38194099

RESUMO

The experience with percutaneous closure of postoperative residual ventricular septal defects (VSDs) is expanding with improved device technology and techniques. To report our experience with percutaneous closure of residual VSDs after cardiac surgeries. Retrospective clinical data review of patients who had percutaneous closure of postoperative residual VSDs at our institution between 2010 and 2022. Patients' demographics, procedural, and follow-up data were looked at. Twelve patients (50% males) with a median age of 9.2 years (range 0.9-22) were identified. Baseline surgeries were 8 tetralogy of Fallot corrections, 2 pulmonary bandings for large muscular VSD (mVSD) including 1 coarctation repair, 1 atrioventricular septal defect repair, 1 sub-aortic membrane resection-induced iatrogenic VSD, 1 isolated VSD closure, and 1 additional mVSD. Median duration between baseline surgery and percutaneous VSD closure was 2.2 years (range 0.2-8.3). Residual VSD shunting was secondary to surgical patch leakage in 8/12 patients. The median angiographic defect diameter was 6.8 mm (range 4.8-14). The defect was balloon-calibrated in 3/12 patients. Defects were tackled retrogradely in 3/9 patients. Amplatzer Membranous VSD occluder (n = 1), Lifetech Multifunctional (n = 5), Membranous (n = 1) and muscular VSD occluders (n = 2) and Occlutech Membranous (n = 1) and Muscular (n = 2) VSD occluders were used. The procedure was successful in 10/12 patients. Two devices embolized to the pulmonary artery and were snare-retrieved. Both patients were referred for surgery. The median follow-up was 1.3 years (range 0.1-12). Six-month ultrasound showed one trivial residual shunt and one mild right ventricular outflow obstruction. One patient is receiving targeted therapy for pulmonary hypertension at 2 years of follow-up. Transcatheter closure of postoperative residual VSDs is a feasible yet challenging intervention. Procedural complications can be encountered.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Comunicação Interventricular , Dispositivo para Oclusão Septal , Masculino , Humanos , Lactente , Pré-Escolar , Criança , Adolescente , Adulto Jovem , Adulto , Feminino , Estudos Retrospectivos , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Dispositivo para Oclusão Septal/efeitos adversos
2.
JMIR Med Inform ; 12: e49986, 2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38241077

RESUMO

BACKGROUND: The increasing population of older adults has led to a rise in the demand for health care services, with chronic diseases being a major burden. Person-centered integrated care is required to address these challenges; hence, the Turkish Ministry of Health has initiated strategies to implement an integrated health care model for chronic disease management. We aim to present the design, development, nationwide implementation, and initial performance results of the national Disease Management Platform (DMP). OBJECTIVE: This paper's objective is to present the design decisions taken and technical solutions provided to ensure successful nationwide implementation by addressing several challenges, including interoperability with existing IT systems, integration with clinical workflow, enabling transition of care, ease of use by health care professionals, scalability, high performance, and adaptability. METHODS: The DMP is implemented as an integrated care solution that heavily uses clinical decision support services to coordinate effective screening and management of chronic diseases in adherence to evidence-based clinical guidelines and, hence, to increase the quality of health care delivery. The DMP is designed and implemented to be easily integrated with the existing regional and national health IT systems via conformance to international health IT standards, such as Health Level Seven Fast Healthcare Interoperability Resources. A repeatable cocreation strategy has been used to design and develop new disease modules to ensure extensibility while ensuring ease of use and seamless integration into the regular clinical workflow during patient encounters. The DMP is horizontally scalable in case of high load to ensure high performance. RESULTS: As of September 2023, the DMP has been used by 25,568 health professionals to perform 73,715,269 encounters for 16,058,904 unique citizens. It has been used to screen and monitor chronic diseases such as obesity, cardiovascular risk, diabetes, and hypertension, resulting in the diagnosis of 3,545,573 patients with obesity, 534,423 patients with high cardiovascular risk, 490,346 patients with diabetes, and 144,768 patients with hypertension. CONCLUSIONS: It has been demonstrated that the platform can scale horizontally and efficiently provides services to thousands of family medicine practitioners without performance problems. The system seamlessly interoperates with existing health IT solutions and runs as a part of the clinical workflow of physicians at the point of care. By automatically accessing and processing patient data from various sources to provide personalized care plan guidance, it maximizes the effect of evidence-based decision support services by seamless integration with point-of-care electronic health record systems. As the system is built on international code systems and standards, adaptation and deployment to additional regional and national settings become easily possible. The nationwide DMP as an integrated care solution has been operational since January 2020, coordinating effective screening and management of chronic diseases in adherence to evidence-based clinical guidelines.

3.
Cardiol Young ; 34(1): 157-162, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37283091

RESUMO

In this multi-centre study, the mid- to long-term efficacy and safety of the Amplatzer Piccolo Occluder in patent ductus arteriosus closure in premature and term infants as well as children were discussed. Methods. Between 2016 and 2021, 645 patients, 152 of whom were less than 1 month old, underwent ductus closure with the Piccolo device from five different centres in Turkey. The median age of the patients was 2.2 years, and the mean narrowest point of duct diameter was 1.8 mm. Sixty-two patients weighed ≤ 1.5 kg, 90 patients 1.5-3 kg, and the mean follow-up was 20.4 months. In 396, the duct was closed by the retrograde route. Ductal anatomy was Type A in 285, C in 72, E in 171, and F in 64 patients. Fluoroscopy duration was 6.2 min. The procedure success rate was 99.1%. Device embolisation occurred in 13 patients (2%), and 11 were retrieved with a snare. Cardiac perforation and death developed in one premature baby. The left pulmonary artery and the descending aorta stenosis were observed in 3 (0.4%) and in 5 patients (0.5%). Results. Piccolo device is safe and effective in closing ductus in all age groups. It has low profile for use in premature and newborn babies, a small embolisation risk, and a low residual shunt rate after closure. Conclusion. The Piccolo device can be considered as close an ideal occluder. The lower profile, smaller delivery catheter size, and symmetry of this device allow for a venous or arterial approach.


Assuntos
Permeabilidade do Canal Arterial , Nascimento Prematuro , Dispositivo para Oclusão Septal , Criança , Lactente , Recém-Nascido , Feminino , Humanos , Adolescente , Pré-Escolar , Resultado do Tratamento , Permeabilidade do Canal Arterial/cirurgia , Cateterismo Cardíaco/métodos , Recém-Nascido Prematuro
5.
Eur Radiol ; 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37947834

RESUMO

OBJECTIVES: The artificial intelligence competition in healthcare at TEKNOFEST-2022 provided a platform to address the complex multi-class classification challenge of abdominal emergencies using computer vision techniques. This manuscript aimed to comprehensively present the methodologies for data preparation, annotation procedures, and rigorous evaluation metrics. Moreover, it was conducted to introduce a meticulously curated abdominal emergencies data set to the researchers. METHODS: The data set underwent a comprehensive central screening procedure employing diverse algorithms extracted from the e-Nabiz (Pulse) and National Teleradiology System of the Republic of Türkiye, Ministry of Health. Full anonymization of the data set was conducted. Subsequently, the data set was annotated by a group of ten experienced radiologists. The evaluation process was executed by calculating F1 scores, which were derived from the intersection over union values between the predicted bounding boxes and the corresponding ground truth (GT) bounding boxes. The establishment of baseline performance metrics involved computing the average of the highest five F1 scores. RESULTS: Observations indicated a progressive decline in F1 scores as the threshold value increased. Furthermore, it could be deduced that class 6 (abdominal aortic aneurysm/dissection) was relatively straightforward to detect compared to other classes, with class 5 (acute diverticulitis) presenting the most formidable challenge. It is noteworthy, however, that if all achieved outcomes for all classes were considered with a threshold of 0.5, the data set's complexity and associated challenges became pronounced. CONCLUSION: This data set's significance lies in its pioneering provision of labels and GT-boxes for six classes, fostering opportunities for researchers. CLINICAL RELEVANCE STATEMENT: The prompt identification and timely intervention in cases of emergent medical conditions hold paramount significance. The handling of patients' care can be augmented, while the potential for errors is minimized, particularly amidst high caseload scenarios, through the application of AI. KEY POINTS: • The data set used in artificial intelligence competition in healthcare (TEKNOFEST-2022) provides a 6-class data set of abdominal CT images consisting of a great variety of abdominal emergencies. • This data set is compiled from the National Teleradiology System data repository of emergency radiology departments of 459 hospitals. • Radiological data on abdominal emergencies is scarce in literature and this annotated competition data set can be a valuable resource for further studies and new AI models.

6.
North Clin Istanb ; 9(2): 183-187, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35582506

RESUMO

Turkey's Corona Precaution Application, a web-based and mobile service, has been actively used by the citizens of the Republic of Turkey and foreigners coming to Turkey since March 19, 2020. This article examines the Corona Precaution Application in terms of its success in detecting risky and positive cases among users. In this informative process analysis study, which is conducted in the lights of Ministry of Health of Turkey data, the efficiency of Corona Precaution Application in March 2020-August 2020 has been measured through the usage statistics from specific provinces and the effect of the application has been proved. The application was used by a total of 2.159.903 people on mobile and web platforms and risk assessments were made. As a result, 135.277 people who were scored as high risk were referred to health-care facilities, and 12.067 people were hospitalized with a positive diagnosis of COVID-19 in PCR tests or isolated at home. When evaluated cumulatively, Corona Precaution Application is used as an effective tool of the health system in the fight against COVID-19. 12.067 people were found to be positive with the referrals to the healthcare facility made through the application; thus, it has been one of the most effective tools in controlling the spread of the disease.

7.
Turk Kardiyol Dern Ars ; 48(4): 403-409, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32519981

RESUMO

OBJECTIVE: The aim of this study was to use tissue Doppler imaging to evaluate the left atrial systolic and the left ventricular (LV) diastolic function as well as the left atrial ejection force in children who underwent transcatheter closure of a secundum atrial septal defect (ASD). METHODS: Tissue Doppler measurements of the left atrial ejection force, the mitral valve, and left atrial volume were performed before the ASD closure procedure, and on the 1st day, 10th day, and 1st and 3rd months after the procedure in 56 patients and in 28 healthy controls. RESULTS: There was a significant decrease in the septal and lateral a' velocities on the first day (p<0.05). There was a statistically significant increase in the septal e'/a' parameters at the third month compared with the initial measurements. The left atrial ejection force was lower in patients with an ASD than in the healthy group (10.69±4.94 kdyn, 12.31±4.05 kdyn, respectively), but there was no significant difference (p=0.053). The left atrial ejection force was significantly greater in the patient group 3 months after the procedure, and there was no significant difference compared with the control group. CONCLUSION: Improvement in the LV diastolic and left atrial systolic functions was observed in children who underwent transcatheter closure of an ASD. There was no negative effect related to the devices used.


Assuntos
Função do Átrio Esquerdo/fisiologia , Cateterismo Cardíaco/efeitos adversos , Comunicação Interatrial/fisiopatologia , Função Ventricular Esquerda/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Cateterismo Cardíaco/instrumentação , Estudos de Casos e Controles , Criança , Pré-Escolar , Diástole , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Estudos Prospectivos , Dispositivo para Oclusão Septal/efeitos adversos , Sístole , Ultrassonografia Doppler/métodos
8.
Echocardiography ; 35(5): 757-759, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29648705

RESUMO

Congenital left atrial appendage aneurysm (LAAA) is a very rare condition and occurs as a result of congenital dysplasia of musculi pectinate. These patients may be asymptomatic and/or may present with dyspnea, and thromboembolic events. The most common complications are life-threatening thromboembolic events and supraventricular tachyarrhythmias. Transthoracic echocardiography plays a very important role in the diagnosis of LAAA. Herein, we present a rare case of giant congenital LAAA.


Assuntos
Apêndice Atrial/anormalidades , Ecocardiografia/métodos , Aneurisma Cardíaco/congênito , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Diagnóstico Diferencial , Feminino , Aneurisma Cardíaco/diagnóstico , Aneurisma Cardíaco/cirurgia , Humanos , Recém-Nascido , Doenças Raras
9.
Anatol J Cardiol ; 18(3): 229-234, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28761023

RESUMO

OBJECTIVE: We prospectively investigated the neoendothelialization of transcatheter secundum atrial septal defect (ASD) closure in children receiving one of three different occluders. METHODS: Transcatheter ASD closure was performed for 44 children. The patients were divided into three groups: group I: Amplatzer, group II: Lifetech CeraFlex, and group III: Occlutech Figulla Flex II septal occluder. The data were prospectively analyzed. Markers of the three phases of wound healing were studied in all patients before and on the 1st and 10th days and 1st month post intervention. RESULTS: The mean age of children was 7.08±3.51 years, and the mean weight was 26.07±15.07 kg. The mean ASD diameter was 12.65±3.50 mm. Groups I, II, and III comprised 34.1%, 31.8%, and 34.1% patients, respectively. No significant differences were observed between the groups regarding patient number, age, defect size, device diameter, or total septum/device ratio (p>0.05). Inflammatory and proliferative phase marker levels increased following the procedure (p<0.05). However, scar formation markers did not change after 1 month. No significant differences in neoendothelializaton were observed among the different occluders (p>0.05). CONCLUSION: All three devices were composed of nitinol with different surface coating techniques. Although the different manufacturing features were claimed to facilitate of neoendothelialization, no differences were observed among the three devices 1 month following the procedure.


Assuntos
Comunicação Interatrial/cirurgia , Dispositivo para Oclusão Septal , Cateterismo Cardíaco , Criança , Desenho de Equipamento , Feminino , Humanos , Masculino , Estudos Prospectivos , Resultado do Tratamento , Cicatrização
10.
Echocardiography ; 34(7): 1105-1106, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28497556

RESUMO

An 11-year-old girl was admitted to pediatric emergency unit with complaints of fatigue and cough. The patient had no previous complaints. There was no history of rheumatic heart disease. The height and duration of the P-wave was 4 mm and 0.16 seconds, respectively (p mitrale). Echocardiography showed enlarged left atrium (51×61 mm in diameter). Both the anterolateral and posteromedial papillary muscles were directly attached to the anterior and posterior mitral valve leaflets without tendinous chords. The patient was diagnosed with mitral arcade, severe mitral stenosis, and mitral regurgitation. The patient was referred to surgery for replacement of mitral valve.


Assuntos
Tosse/etiologia , Fadiga/etiologia , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/complicações , Estenose da Valva Mitral/diagnóstico por imagem , Criança , Ecocardiografia/métodos , Feminino , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/fisiopatologia , Estenose da Valva Mitral/fisiopatologia
11.
Echocardiography ; 33(9): 1397-401, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27146071

RESUMO

AIM: This study aimed to evaluate ventricular diastolic dysfunction, inter- and intraatrial conduction delay, and P-wave dispersion in pediatric patients with subclinical hypothyroidism. METHODS: The study comprised a total of 30 pediatric patients with subclinical hypothyroidism (SH) (mean age 7.8 ± 3.2 years) and 30 healthy children (mean age 8.4 ± 3.6 years) as the control group. A SH diagnosis was made in the event of increased serum thyroid-stimulating hormone (TSH) and decreased serum free triiodothyronine (T3 ) and free thyroxine (T4 ) concentrations. RESULTS: Conventional Doppler imaging (TDI) showed low mitral early diastolic E-wave velocity and E/A ratio (P < 0.001) and significantly higher mitral late diastolic A-wave velocity (P = 0.001) in hypothyroidism patients. Moreover, patients with hypothyroidism had significantly lower left ventricular (LV) septal Em velocity and Em /Am ratios compared with the control group (P < 0.001), whereas Am velocity was higher in hypothyroidism patients (P = 0.018). LV lateral Em velocity and Em /Am ratio were significantly lower in patients with hypothyroidism compared with the control group (P < 0.001). With regard to atrial electromechanical conduction, atrial electromechanical delay (PA) lateral, PA septum, PA tricuspid, and each of interatrial and intraatrial conduction delay were significantly prolonged in hypothyroidism patients as compared with the control group (P < 0.001, P < 0.001, P = 0.023, P = 0.002, and P = 0.003, respectively). P-wave dispersion was significantly different in the pediatric patients with hypothyroidism (P < 0.001). CONCLUSION: This study demonstrated atrial electromechanical conduction delay, abnormal P-wave dispersion, and ventricle diastolic dysfunction in pediatric patients with hypothyroidism.


Assuntos
Ecocardiografia Doppler/métodos , Hipotireoidismo/complicações , Hipotireoidismo/fisiopatologia , Contração Miocárdica , Volume Sistólico , Disfunção Ventricular Esquerda/etiologia , Doenças Assintomáticas , Criança , Acoplamento Excitação-Contração , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Humanos , Hipotireoidismo/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Infarto do Miocárdio , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...